site stats

Liner exchange in revision hip arthroplasty

Nettet10. jun. 2024 · One of the more frequently performed current revision hip arthroplasties involves isolated acetabular liner exchange. Although liner exchange may appear to both the surgeon and the patient to be a relatively simple operative intervention, it has been plagued by postoperative dislocation when performed via a posterior approach. Nettet19. sep. 2024 · Polyethylene (PE) wear remains a common reason for revision surgery following total hip arthroplasty (THA). An established treatment method is isolated …

Does Approach Influence the Dislocation Rate Following Head and …

Nettet10. apr. 2024 · Antibiotic-loaded cement spacers. A typical knee or hip antibiotic-loaded spacer is shown in Fig. 1. Antibiotic-loaded spacers have two primary roles in two-stage exchange arthroplasty: filling the joint cavity, which tensions the soft tissues while restoring limb length, and antibiotic elution. Nettet19. nov. 2010 · Revision of a total hip arthroplasty needs comprehensive knowledge of the characteristics of the articulating materials. A wrong choice of wear couple can lead … peoplesoft company table https://srdraperpaving.com

Clinical outcomes and dislocation rates after hip reconstruction …

Nettet1. sep. 2024 · Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup... Nettet1. nov. 2024 · Background and Objectives: Femoral head and liner exchange is an established treatment for polyethylene wear but has had a more limited role in the … Nettet13. apr. 2024 · The outside diameter of the liners after revision was 50 mm, and the femoral head was 28 mm in diameter. In addition, loosening on the femoral side had been ruled out in all patients on preoperative radiographs and intraoperative examinations, so revision of the femoral prosthesis was not required. toifs1

Polyethylene Liner and Femoral Head Exchange in Total Hip Arthroplasty

Category:High risk of hip dislocation following polyethylene liner exchange …

Tags:Liner exchange in revision hip arthroplasty

Liner exchange in revision hip arthroplasty

Medicina Free Full-Text Femoral Head and Liner Exchange in …

Nettet1. feb. 2024 · Isolated head and liner exchange in revision total hip arthroplasty (THA) is an appealing treatment option for well-fixed, appropriately positioned implants. …

Liner exchange in revision hip arthroplasty

Did you know?

Nettet9. des. 2016 · In revision THA, isolated liner exchange is a common surgical intervention when the acetabular component remains well fixed. The intervention has several advantages, such as decreased morbidity and preservation of pelvic bone stock. Either the original locking mechanism or cement may be used to fix the revision liner into the … NettetIn this procedure, your doctor will open up your hip, wash out the bacteria, and exchange the ball and plastic liner. The metal implants that are firmly attached to the bone are left in place. After debridement, you will …

Nettet20. feb. 2024 · Purpose Although rare, fractures of ceramic components are difficult to revise, mainly due to the presence of residual ceramic debris that can cause catastrophic wear of the replacement components. Modern ceramic-on-ceramic bearings are suggested to improve outcomes of revision total hip arthroplasty (THA) for ceramic fractures. … NettetBackground: Revision total hip arthroplasty with modular component exchange can limit morbidity by retaining well-fixed components but dislocation has been a …

Nettet18. okt. 2024 · Liner Exchange for Wear and Osteolysis after Total Hip Arthroplasty FEATURING Peter KY Chiu 11 views October 18, 2024 10:18 Arthroplasty Society in Asia Direct Anterior Simple Primary to Revision FEATURING Brent Lanting 410 views October 18, 2024 1 12:09 Arthroplasty Society in Asia Robotic Acetabular … NettetAll patients with a periprosthetic fracture of the femur after a total hip arthroplasty, having femoral revision at our institution between January 2010 and December 2024, were enrolled in this retrospective analysis ( Supplementary Table 1 ). In total, 37 revision hip arthroplasties were done in 16 men (43%) and 21 women (57%).

Nettet1. feb. 2024 · Volume 37, Issue 2, February 2024, Pages 336-341 Revision Arthroplasty Does Approach Influence the Dislocation Rate Following Head and Liner Exchange in …

Nettet6. mar. 2024 · Background: Polyethylene (PE) liner and femoral head exchange is commonly used to treat periprosthetic osteolysis associated with PE wear after total hip … toi foxx hair studiosNettet6. mar. 2024 · Polyethylene (PE) liner and femoral head exchange is commonly used to treat periprosthetic osteolysis associated with PE wear after total hip arthroplasty (THA). The purpose of our study was to determine long-term implant survivorship, risk factors for mechanical failure, clinical outcomes, and complications following PE liner and head … peoplesoft competitionNettetIn the setting of osteolysis, outcomes associated with the use of highly cross-linked polyethylene liners have been better than those associated with the use of conventional … peoplesoft compensationNettetThe aim of the present study was to evaluate the dislocation rate and the risk factors leading to instability after primary and revision total hip replacement arthroplasty (THRA) with constrained acetabular liners … toi free crosswordNettet1. apr. 2024 · Background: Modular dual mobility (MDM) acetabular components have become increasingly more popular in total hip arthroplasty (THA). Uncertainty remains regarding liner malseating and its ... peoplesoft component interface not authorizedNettetDislocation after polyethylene liner exchange in total hip arthroplasty. Little has been published on the outcomes of polyethylene liner exchanges for wear or osteolysis. We … peoplesoft component interface methodsNettet1. apr. 2024 · We identified 138 hips in 132 patients who underwent isolated head and liner exchange for wear/osteolysis (57%), acute infection (27%), metallosis (13%), or … peoplesoft component without search record